High Power Resistor Load Bank

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2022-02-13 06:41
Browse the number: 455
inquiry
Company Profile
 
 
Product details


PRODUCT OVERVIEW


High power resistor load bank is mainly used in the performance testing and aging of online high-power UPS, inverter, switching power supply and diesel generator set of power, telecommunications and other departments and manufacturers. Unified segmented power input, energy consumption working mode and forced air cooling heat dissipation greatly ensure the reliability of constant power discharge; The internal heat dissipation element adopts dry resistance and forced air cooling heat dissipation. Produced with independent intellectual property rights of new power consumption components, it has high power density, no red heat phenomenon and automatic overheating protection function. When the fan does not turn, it will not overheat and burn loss, and has a long safety life; The whole machine adopts modular design, with simple operation and convenient maintenance; It can test voltage, current and other parameters according to customer requirements, which provides a scientific detection means for high-power AC power supply equipment.


PRODUCT PICTURE




PRODUCT DETAILS




APPLICATION SCENARIO



PARTIAL PARAMETERS



Note: all parameters are for reference only and can be customized

Product name

high power resistor load bank

Specifications

R5000kW/10.5kV/400V/50Hz

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load step

According to customer needs

Load connection

Copper bar

Resistor

Each resistance element: insulation impedance DC1000V/100MΩ above

Withstand voltage ac 2000v for 5min

Resistance error of each resistance tube:±3%

Load control

Local manual control, local automatic control or remote automatic control can be selected

Loading accuracy

Less than or equal to 3%

Three phase balance

Unbalance degree less than or equal to 3%

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

TN-C,380V/50Hz

Cooling mode

Forced air cooling, side air outlet or top air outlet

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, etc

Voltage rising mode

Realized by transformer

Load expansion

Parallel expansion of multiple load containers

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation

Color

Customized

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa


MORE SPECIFICATIONS



Note: all parameters are for reference only and can be customized

Power(kW)

Voltage(kV)

Frequency(Hz)

Size(mm,L*W*H)

Weight(Kg)

Low voltage

100

0.4

50

1100*900*1000

320

200

0.4

50

1350*1100*1100

450

300

0.4

50

1500*1200*1200

650

400

0.4

50

1700*1500*1500

830

500

0.4

50

1700*1600*1600

950

600

0.4

50

1800*1600*1600

1150

800

0.4

50

1900*1800*1700

1900

1000

0.4

50

2300*1700*2100

2100

1200

0.4

50

2500*1800*2200

2300

1500

0.4

50

2500*1860*2300

2600

1800

0.4

50

3000*2000*2300

4000

2000

0.4

50

3000*2000*2300

5000

2500

0.4

50

4000*2438*2500

6000

3000

0.4

50

6000*2438*2500

7000

Medium voltage

1000

6/10.5

50/60

3000*2438*2500

3500

1200

6/10.5

50/60

4000*2438*2500

3900

1500

6/10.5

50/60

4000*2438*2500

4500

1600

6/10.5

50/60

5000*2438*2500

5000

1800

6/10.5

50/60

5000*2438*2500

6500

2000

6/10.5

50/60

6000*2438*2500

7500

2200

6/10.5

50/60

6000*2438*2500

8000

2500

6/10.5

50/60

6000*2438*2500

10000

3000

6/10.5

50/60

7000*2438*2500

12000

4000

6/10.5

50/60

8000*2438*2500

14000

5000

6/10.5

50/60

9000*2438*2500

15000

6000

6/10.5

50/60

12000*2438*2500

16000

7000

6/10.5

50/60

12000*2438*2500

17000

8000

6/10.5

50/60

12000*2438*2500

18000


DESIGN DRAWINGS




TRANSPORT AND INSTALL



The top four corners of the load bank are provided with lifting holes and the bottom four corners are provided with rollers to facilitate loading, transportation and mobile installation.


HIGH VOLTAGE LOAD BANK COMPONENTS


High voltage vacuum circuit breaker

VS1 (ZN63A) indoor high voltage vacuum circuit breaker is an indoor switchgear used in 10kV power system. It is the protection and control unit of power grid equipment and power equipment of industrial and mining enterprises. Due to the special advantages of vacuum circuit breaker, it can be used in places requiring frequent operation of rated working current or breaking short-circuit current for many times.

Vacuum circuit breaker mainly includes three parts: vacuum arc extinguishing chamber, electromagnetic or spring operating mechanism, support and other components.

Product basis standard:

GB/T1984-2014 High voltage AC circuit breaker

GBT11022-2011 Common technical requirements for high voltage switchgear and control equipment standards

Low voltage circuit breaker

Sya series intelligent universal circuit breaker (hereinafter referred to as circuit breaker) is applicable to the distribution network with AC 50Hz, rated voltage of 400V / 690V and below and rated current of 630A to 6300A. It is used to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. The circuit breaker has intelligent protection function and accurate selective protection, which can improve the reliability of power supply and avoid unnecessary power failure. At the same time, it has an open communication interface, which can carry out "four remotes" to meet the requirements of control center and automation system. When the circuit breaker is 2000m above sea level, the pulse withstand voltage is 8000V. The maximum voltage at different altitudes is not more than 12000V. The circuit breaker can be used as an isolator without intelligent controller and sensor.

The circuit breaker shall comply with GB14048 2 low voltage circuit breakers for low voltage switchgear and control equipment and IEC60947-2 circuit breakers for low voltage switchgear and control equipment.


HONORARY QUALIFICATION


Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.



http://www.cnloadbank.com/

Total0bar [View All]  Related Comments
 